EVI 10000VA / 9000W Tower, Online Single Phase UPS, EP-UPS10000Y11OT
$59.3
$97.85
EVI 10000VA / 9000W Tower, Online Single Phase UPS, EP-UPS10000Y11OT. For environments where power continuity is paramount—such as small data centers, telecom racks, medical setups, or critical industrial equipment—the EVI 10000VA / 9000 W Tower Online UPS delivers dependable, high-performance electrical protection. Purposely designed with double-conversion technology and advanced power conditioning, this robust EVI 10000VA / 9000 W Tower Online UPS ensures seamless operations, minimal downtime, and superior energy efficiency. Imagine no sudden reboots, no data loss, and optimal uptime, thanks to its comprehensive safety and redundancy features. Let’s explore what makes this EVI 10000VA / 9000 W Tower Online UPS a reliable backbone for sensitive systems. Key Benefits & Highlights Continuous Clean Power via Double-Conversion Online TopologyProvides pure, regulated sine wave output, isolating critical loads from power grid instability. High Real-World Power DeliveryRated at EVI 10000VA / 9000 W Tower Online UPS with a high output power factor of 0.9, delivering the full 9000 W capacity. Minimal Input DistortionEVI 10000VA / 9000 W Tower Online UPS Input current harmonic distortion is under 3%, thanks to intelligent DSP control—promoting cleaner operation and compatibility with sensitive electronics. Wide Input Voltage and Frequency BandsEVI 10000VA / 9000 W Tower Online UPS Operates across 120–276 VAC, and supports both 50 Hz (45–55 Hz) and 60 Hz (54–66 Hz) frequency ranges—ideal for variable grid or generator inputs. Flexible Charging OptionsEVI 10000VA / 9000 W Tower Online UPS Allows selection between 1 A or 2 A charging currents, adapting to single or dual battery bank setups for performance tuning. Built-In ECO & Self-Test ModesBoosts efficiency in stable conditions using ECO mode whilst performing comprehensive diagnostic checks at startup. Rich Communication & CustomizabilityIncludes USB and RS232 ports, with optional SNMP, parallel, and relay cards for scalable, networked deployment. Cold Start & Rotating LCDEVI 10000VA / 9000 W Tower Online UPS Capable of powering up directly from battery (cold start), and features a rotatable LCD interface for easy readability—from any installation orientation. Safety EnhancementsEVI 10000VA / 9000 W Tower Online UPS Equipped with Emergency Power Off (EPO) capability and a terminal block for wired input/output integration. Technical Overview (Bullet Format) Model: EP‑UPS10000Y11OT Topology: Online Double-Conversion (DSP Controlled) Design: Tower Form Factor Rated Capacity: 10000 VA / 9000 W (Output PF 0.9) Input Voltage Range: 120–276 VAC Input Frequency Range: 50 Hz: 45–55 Hz 60 Hz: 54–66 Hz Input Current Harmonics: < 3% Charging Current Options: 1 A or 2 A (2A for dual battery banks) ECO & Self-Test Modes: Built-in Generator Compatibility: Yes Cold Start Capability: Yes Display: Rotating LCD Screen Emergency Power Off (EPO): Supported (via terminal block) Communication Ports: USB RS232 Optional: SNMP card, Parallel card, Relay card Low-Priority Load Shutdown: Supported Battery Type: Sealed Lead-Acid (SLA) or Optional Lithium Typical Backup Time: 15–30 minutes at typical load (approximate reference) Battery Bank: 16 × 7 Ah batteries (based on related product specs) Alarm System: Audible alerts for power, low battery, overload, and fault conditions Dimensions: ~438 mm (W) × 500 mm (D) × 88 mm (H) Weight: ~18 kg Operating Conditions: Temp: 0–40 °C Humidity: Up to 95% (non-condensing) Noise: < 55 dB @ 1 m
Accessories